Tel:86-10-8404-4009

Home>Application>Solar

Return list >

Freeze Protection

Open~Close Temperature:1°C-4°C

Maximum Operating Temperature:130°C

Flow Rate(Cv):0.6

ReadingDownload

Specification

Model

 Port 

Size

Open~Close Temperature

Maximum Operating Temperature

Maximum Operating Pressure

Dimension

Net Weight

Flow Rate

°C

°F

°C

°F

MPa

PSI

mm

Inch

g

lb

Cv

FP15-35

1/2”NPT

1--4

33.8--39.2

130

266

1.0

145

Φ30*69

1.18*1.18*2.71

130

0.287

0.6

FP15-45

1/2”NPT

3--6

37.4--42.8

130

266

1.0

145

Φ30*69

1.18*1.18*2.71

130

0.287

0.6

Freeze Protection Principle: 

When the temperature approaches freezing, the valve opens to discharge the cold water and recloses upon warmer water replacement. This cycle continues preventing panel and piping freeze up.

SELF-ACTUATOR (open/close): NO ELECTRICAL POWER, NO MANUAL WORK!


Design Features

Easy installation with pipe wrench

Discharges the minimum amount of water required to prevent freeze damage

Sensitive to temperature only


Compare (Freeze Protection Solutions):


Freeze Protection Valve

Electrical Heat Tracing

Air Release Valve

Forced-Circulation System

Fluid Medium

Installation

Easy

Complicated

Complicated

Complicated

Average

Safety

High

Low (Power Off)

Low (Power Off)

Low (Power Off)

Low

Maintenance

Easy

Complicated

Complicated

Complicated

Complicated

Application

Panel, Pipe Line

Pipe Line

Pipe Line

Pipe Line

Panel


Application:

Western Yard, Yard No. 18, Babeicun, Taiyanggong, | Tel:86-10-8404-4009 | Website:www.valcoo.com