Home>Product>Mixing Valve
Model |
Port Size | Temperature (Central Degree) Setting | Accurate | Maximum Operating Temperature | Maximum Operating Pressure | Net Weight | Flow Rate | |||||
°C | °F | °C | °F | °C | °F | MPa | PSI | g | lb | Cv | ||
MD | DN15 | 37/45/55/60/required | 98.6/113/131/140/required | ±2 | ±3.6 | 130 | 266 | 1.0 | 145 | 290 | 0.639 | 1.5 |
DN20 | 335 | 0.738 | 1.5 |
Cold Water Temperature Range: Any but lower than the setting temperature
Cold Water Temperature Range: Any but higher than the setting temperature
Example:
Setting at 45°C (113°F),
Cold water temperature range:5°C(41°F) to 45°C (113°F)
Hot water temperature range:45°C(113°F) to 100°C (212°F)
Easy installation with pipe wrench
Discharges the minimum amount of water required to prevent freeze damage
Sensitive to temperature only
Western Yard, Yard No. 18, Babeicun, Taiyanggong, | Tel:86-10-8404-4009 | Website:www.valcoo.com
Contact usBeijing Winning Thermo Control Equipment Co., Ltd
亿网中国 网站建设